Hanna Instruments HI 93703 Portable Microprocessor Turbidity Meter Instruction Manual

The HI 93703 Portable Microprocessor Turbidity Meter allows for high-precision turbidity measurements in both the field and the laboratory. The meter has a range of 0 to 1000 FTU, divided into two scales: 0.00 to 50.00 FTU and 50 to 1000 FTU. The auto-ranging feature automatically sets the appropriate range for the measurement. The HI 93703 is designed according to the ISO7027 International Standard, with the turbidity unit being FTU (Formazine Turbidity Unit), which is equivalent to the internationally recognized unit NTU (Nephelometric Turbidity Unit).


Hanna Instruments HI 93703 Portable Microprocessor Turbidity Meter Instruction Manual - cover page
Brand
Hanna Instruments
Category
Other Electronics
Document type
User Manual
Language
English
Pages
13
File format
PDF
File size
701 KB
Published
10 July, 2012
Updated
28 September, 2023
MD5 checksum
0D84AD2DCA06B7F943D74338824CB3A5

About this manual

The HI 93703 is a portable, microprocessor-based instrument designed to determine the turbidity of water and wastewater according to ISO 7027 International Standard. It features an auto-ranging capability with two scales (0.00-50.00 FTU and 50-1000 FTU) and uses an infrared LED light source peaking at 890 nm to minimize interference from colored samples.

The manual details the operational guide, including how to insert batteries, turn on the device, and perform measurements using glass cuvettes. It also explains the calibration procedure, which supports one-point or three-point calibration using specific standard solutions (HI 93703-0, HI 93703-10, and HI 93703-50). Additionally, it covers troubleshooting sources of interference such as air bubbles, floating debris, and dirty glassware.

What's inside

  • Preliminary examination
  • General description
  • Principle of operation
  • Specifications
  • Functional description
  • Operational guide
  • Measurement procedure
  • Calibration
  • Sources of interference
  • Warranty

Specifications

Range0.00 to 50.00 FTU; 50 to 1000 FTU
Resolution0.01 and 1 FTU
Accuracy±0.5 FTU* or ±5% of reading (whichever is greater)
Light SourceInfrared LED peaking at 890 nm
Battery Type4 x 1.5V AA alkaline
Battery LifeApprox. 60 hours of use or 900 measurements
Dimensions220 x 82 x 66 mm (8.7 x 3.2 x 2.6")
Weight510 g (1.1 lb.)

Frequently asked questions

What is the turbidity unit used by this meter?

The instrument uses FTU (Formazine Turbidity Unit), which is equivalent to NTU.

How often should the meter be calibrated?

A monthly calibration is recommended, though more frequent checks are suggested for greatest accuracy.

What causes false readings on the turbidity meter?

False readings can be caused by floating debris, air bubbles, vibrations disturbing the sample surface, and dirty glassware.

How long does it take to perform a measurement?

The turbidity value appears after approximately 25 seconds.