The TWINMATE L-208 is a light meter device that requires caution regarding the safety of infants and young children. It warns against accidental choking and swallowing of batteries. It also provides light metering functionality and the ability to mount it on a camera.
This document is the user manual for the Sekonic L-208 TwinMate, an analog ambient light meter. It provides instructions on how to install the strap and the CR2032 lithium battery, and explains how to verify the battery charge using the indicator button. The manual details the selection of ISO sensitivity and the use of the measurement button to capture readings. This manual is written in Spanish.
| Model | Analog ambient light meter |
|---|---|
| Light Receiving Method | Incident and reflected light |
| Light Receiving Part | Incident light (flat type) |
| Light Receiving Part | Reflected light (33 degree angle) |
| Light Receiving Element | Silicon photodiode |
| Measurement Range | EV3 ~17 |
| ISO Sensitivity | 12 ~12500 |
| Aperture | 1.4 ~ 32 |
| Shutter Speed | 30 seconds ~1/8000 |
| Power Supply | 3V CR2032 lithium coin battery |
| Operating Temperature | 0 ~ 40*C |
| Storage Temperature | -20*C ~ 60*C |
| Dimensions | 45x65x24 mm |
| Weight | 40 grs. |
The device requires a 3V CR2032 lithium coin battery.
Press the battery verification button before use; if the indicator needle is outside the battery charge frame, the battery must be replaced.
The reflected light receiving angle is approximately 33 degrees.
The shutter speed range is from 30 seconds to 1/8000.