Agilent 7200 Q-TOF for GC/MS Product Brochure

Agilent 7200 Q-TOF for GC/MS is a multi-purpose mass spectrometry system that provides the highest levels of qualitative and quantitative analysis. The system combines the separation capabilities of the Agilent 7890 series GC with the MS components of the 7000 series triple quadrupole GC/MS and 6500 series LC/Q-TOF systems to provide robust GC/MS operation, excellent selectivity, high-sensitivity full-scan acquisition, and fast data acquisition, as well as accurate mass data that facilitates molecular characterization and structural analysis.


Agilent 7200 Q-TOF for GC/MS Product Brochure - cover page
Brand
Agilent
Document type
Product Leaflet
Language
Japanese
Pages
16
File format
PDF
File size
8.6 MB
Published
06 July, 2012
Updated
30 September, 2023
MD5 checksum
23FFE7B4C90665F5772A967A99150BFD

About this manual

The Agilent 7200 Q-TOF for GC/MS is described as the world's first quadrupole time-of-flight (Q-TOF) gas chromatography-mass spectrometry system. It combines the proven performance of the Agilent 7890 Series GC with TOF analyzer capabilities to provide high-resolution, accurate mass data for complex matrices and trace-level analysis.

Key features include a quadrupole ion trap collision cell for high-quality MS/MS spectra, orthogonal TOF technology, and an internal reference mass (IRM) correction system. The system supports up to 350°C temperature programming and includes a replaceable ion source that can be changed in approximately 30 minutes without breaking vacuum. This manual is written in Japanese.

What's inside

  • System Overview
  • High Resolution and Mass Accuracy
  • MS/MS Selectivity
  • Internal Reference Mass (IRM)
  • Replaceable Ion Source
  • Temperature Programming
  • Data Analysis Software

Frequently asked questions

What is the resolution of the Agilent 7200 Q-TOF for GC/MS?

The system achieves a resolution of 13,500 (FWHM), allowing it to easily distinguish between two compounds with nominal masses of 240 Da and an actual mass difference of just 0.0436 Da.

How long does it take to replace the ion source?

The new replaceable ion source (RIS) allows for changing the entire ion source assembly in approximately 30 minutes without breaking vacuum.

What is the maximum temperature programming capability?

The system features a high-sensitivity extraction source capable of temperature programming up to 350°C.

Download PDF (8.6 MB)

More Agilent Manuals