German Pool GPR-V600 Installation Guide


German Pool GPR-V600 Installation Guide - cover page
Brand
GermanPool
Category
Range hoods
Document type
Installation Guide
Language
English
Pages
12
File format
PDF
File size
208 KB
Published
10 April, 2012
Updated
09 April, 2012
MD5 checksum
52FDC2951179AE47B84A690D65830D79

About this manual

This guide covers the installation, electrical connection and use of the German Pool GPR‑V600 kitchen hood. It explains the two possible operating modes – suction (exhaust to the outside) and filtering (recirculation with active carbon filters) – and details the required clearances and mounting procedures.

Key sections describe the technical characteristics, wall‑mounting template, extendible tube assembly, control panel functions, and routine maintenance such as cleaning the grease filter and replacing the light bulb. Safety warnings and warranty information are also included.

What's inside

  • General Indications
  • Technical Characteristics
  • Installation
  • Suction Mode
  • Filtering Mode
  • Wall Mounting
  • Electrical Connection
  • Control Panel
  • Maintenance
  • Guarantee

Specifications

Total power280W
Motor power200W
Lights2 × 40W

Frequently asked questions

How should the hood be installed for suction mode?

Connect the 125 mm diameter plastic conical outlet piece supplied with the hood to an exhaust pipe that leads directly outside.

How often must the active carbon filters be replaced?

The active carbon filters should be replaced at least once every three months, depending on how often the hood is used.

What is the minimum distance required between the hood and the stove top?

The hood must be installed at a minimum distance of 66 cm from the stove top.

What type of light bulb can be used when changing the light?

An oval light bulb of no more than 40 W may be used.