About this manual

The Altivar 71 Crane Card VW3A3510 is an option card designed for use with Altivar 71 and Altivar 31 variable speed drives running firmware version V1.2 or above. The card supports specific crane applications, including anti-sway operator assistance, cable length acquisition, and various input/output functions for limit switches and slowing down switches.

The document details the hardware setup, including terminal descriptions for power supply, logic inputs/outputs, and analog I/O. It also covers configuration procedures via the [1.14 Crane] menu, CANopen connection setup, and commissioning steps for motor parameters and wiring.

What's inside

  • Description of the terminals
  • Characteristics
  • Data backup battery
  • Operating principle
  • Anti-sway operator assistance
  • Cable length acquisition
  • Input/Output functions
  • Assistance activation function
  • End limit switch function
  • Slowing down switch function

Specifications

Power supply voltage24 Vc (min. 19, max. 30)
Current consumption (no-load)80 mA
Logic inputs impedance4.4 kΩ
Logic outputs typePositive logic open collector
Battery life8 years

Frequently asked questions

Which firmware versions are supported by this card?

The card is fully supported with Altivar 71 firmware version V1.2 and above, and Altivar 31 firmware version V1.2 and above.

What is the maximum current for the logic outputs?

The maximum current for the logic outputs is 200 mA.

Can the crane card be powered by the drive's internal supply?

Yes, if the power consumption does not exceed 200 mA; otherwise, an external 24 Vc power supply is required.