The document describes the features and characteristics of Hisense products.
The manual introduces the Hisense KFR-35GW/11FZBp-4 split heat pump wall‑mounted air conditioner, outlining its main features, safety precautions, and component overview. It emphasizes the need for proper grounding, warns against unauthorized modifications, and advises disconnecting power before any work.
Detailed installation instructions cover site preparation, electrical wiring, refrigerant piping, mounting of indoor and outdoor units, and drainage setup. The guide also lists the product’s main technical specifications, cleaning and maintenance procedures, and troubleshooting tips. This manual is written in Chinese.
| Model | KFR-35GW/11FZBp-4 |
|---|---|
| Power supply voltage | AC 220V |
| Power supply frequency | 50 Hz |
| Indoor unit weight | 9.0 kg |
| Indoor noise level (minimum) | 25 dB |
| Operating temperature range (heating) | -7 °C to 43 °C |
| Operating temperature range (cooling) | 18 °C to 43 °C |
The indoor unit is linked to the outdoor unit with refrigerant piping (联机配管) that circulates the refrigerant between the two units.
The heating mode can operate down to –7 °C (up to 43 °C), while the cooling mode works from 18 °C to 43 °C.