Charm Faith Autosystem SWP-SX100 Audio Alarm User Manual

This document is the user manual of the SWP series audio alarm, which introduces the characteristics of the product, including simple external wiring, convenient installation, long service life, high sound efficiency and low power consumption, and can accept contact input signals.


Charm Faith Autosystem SWP-SX100 Audio Alarm User Manual - cover page
Brand
swp
Category
Other
Document type
User Manual
Language
Chinese
Pages
1
File format
PDF
File size
98 KB
Published
14 March, 2012
Updated
30 September, 2023
MD5 checksum
F81CCFF1AB440BEEA7260C1469B85134

About this manual

The SWP‑SX100 audio alarm is designed with a dedicated alarm‑sound chip and integrated audio power amplifier, providing bright, pure‑tone alerts. It can be used together with flashing alarms or as a standalone sound alarm.

Key features include simple external wiring, DIN‑rail mounting, a wide operating temperature range, low power consumption, and two selectable alarm tones. The device accepts high‑level voltage or contact inputs and includes a self‑test button for quick verification. This manual is written in Chinese.

What's inside

  • Overview
  • Technical Parameters
  • Input Signal
  • Alarm Sound
  • Self‑test Function
  • Environmental Conditions
  • Power Supply
  • Construction
  • Installation
  • Wiring Diagram

Specifications

Input voltage level5 V – 24 V (high level)
Alarm tone selectionTwo tones
Self‑testPress test switch to emit sound
Operating temperature-10 °C – +55 °C
Relative humidity≤85 % (no condensation)
Power supplyDC24 V or AC220 V
Power consumption (alarm)≤8 W
Power consumption (idle)≤0.1 W
Dimensions142 × 115 × 35 mm
Weight500 g

Frequently asked questions

What power sources can the SWP‑SX100 use?

It can be powered by either DC 24 V or AC 220 V.

How much power does the alarm draw when it sounds?

During an alarm it consumes up to 8 W, and only 0.1 W when idle.

Can the device be tested without an external alarm signal?

Yes, pressing the test switch makes the audio alarm emit sound.

What are the environmental limits for operating the alarm?

It works from –10 °C to +55 °C and up to 85 % relative humidity without condensation.

Download PDF (98 KB)

More swp Manuals