WT door access device installation and operating manual, introduces the application range, performance characteristics, installation instructions, first power on use, operating instructions, swipe card to open the door, initialization, common problems and solutions, technical parameters, etc.
This manual provides step‑by‑step instructions for installing the WT access control device, including mounting the reader and controller, wiring diagrams, and power requirements. It also explains the initial power‑on procedure and how to program and erase access cards.
Additional sections cover system features, initialization methods, common troubleshooting questions, and detailed technical specifications such as voltage, current, relay ratings, and environmental limits. This manual is written in Chinese.
| Working voltage | DC 9‑40 V, AC 8‑36 V |
|---|---|
| Working current | <150 mA |
| Peak current | 200‑300 mA (depends on relay count) |
| Relay count | 4 |
| Relay voltage rating | DC 60 V, AC 125 V |
| Relay current rating | max 2 A (impulse), max 1 A (continuous) |
| Power consumption | max 30 W / 60 VA |
| Data retention after power loss | 10 years |
| Protection rating (reader) | IP65 |
| Operating temperature (reader) | -20 °C to +70 °C |
| Operating humidity (non‑condensing) | 0‑95 % |
| Maximum cable length | 100 m (using J‑Y (St) 2×2×0.8 cable) |
| Installation standard | DIN EN 50022 rail mounting |