Testo 405-V1 Thermal Wind Speed Instrument User Manual

This is the manual for testo 405-V1 thermal anemometer, including power on/off, parameter switching, pipe cross-section setting, etc.


Testo 405-V1 Thermal Wind Speed Instrument User Manual - cover page
Brand
testo
Category
Other device
Document type
User Manual
Language
Chinese
Pages
1
File format
PDF
File size
201 KB
Published
15 February, 2012
Updated
30 September, 2023
MD5 checksum
305A9B27BC04DF65F686E1D94668252A

About this manual

This manual describes the functions and proper use of the Testo 405‑V1 thermal wind speed instrument. It includes guidance on measuring wind speed and temperature, setting up the device, and interpreting the displayed values.

The document also covers calibration procedures, sensor replacement, warranty information, and safety notes such as avoiding operation outside the specified temperature limits and handling the sensor correctly. This manual is written in Chinese.

What's inside

  • Measurement range
  • Operating temperature
  • Calibration procedure
  • Sensor replacement
  • Warranty and CE compliance
  • Safety notes

Specifications

Wind speed range (low temperature)0‑5 m/s (-20 °C to 0 °C)
Wind speed range (high temperature)0‑10 m/s (0 °C to 50 °C)
Operating temperature range-20 °C to 50 °C
Storage temperature range-20 °C to +70 °C
Sensor diameter127 mm
Sensor length150‑300 mm
Warranty period1 year

Frequently asked questions

What temperature range can the instrument operate in?

The device operates between –20 °C and 50 °C.

How long is the warranty for the Testo 405‑V1?

The instrument has a warranty period of one year.

What should be done if the sensor display indicates a fault?

Replace the sensor according to the replacement procedure described in the manual.