Motorola MMA1200D Accelerometer Datasheet

This document is the technical data manual of MMA1200D, which introduces the product's features, performance, applications and other information.


Motorola MMA1200D Accelerometer Datasheet - cover page
Brand
Motorola
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
9
File format
PDF
File size
265 KB
Published
14 February, 2012
Updated
30 September, 2023
MD5 checksum
9DDF11528C28DEBFFA10528F66D010AD

About this manual

The MMA1200D is a surface‑micromachined silicon capacitive accelerometer with integrated signal‑conditioning, a 4‑pole Bessel low‑pass filter, and temperature compensation. It offers a linear output, self‑test capability, and fault‑latch status monitoring, making it suitable for vibration, impact, and airbag applications.

The datasheet lists electrical ratings, mechanical characteristics, package dimensions, and recommended PCB layout. Key parameters such as supply voltage range, sensitivity, bandwidth, and zero‑g output are provided, along with pin assignments and ordering information for the SOIC‑16 (Case 475‑01) package.

What's inside

  • Features
  • Maximum Ratings
  • Operating Characteristics
  • Principle of Operation
  • Special Features
  • Pinout Description
  • Package Dimensions
  • Ordering Information
  • Self‑Test and Status

Specifications

Supply Voltage0.3 V to +7.0 V
Supply Current3.0 mA – 6.0 mA
Operating Temperature Range-40 °C to +85 °C
Sensitivity1.47 – 1.72 mV/g
Bandwidth360 Hz – 440 Hz

Frequently asked questions

What is the supply voltage range for the MMA1200D?

The device operates from 0.3 V up to +7.0 V supply voltage.

How does the self‑test function work?

Applying a logic high to the self‑test pin drives a calibrated potential across a dedicated test plate, causing the sensing plate to deflect; the resulting output verifies both mechanical and electrical integrity.

When does the Status pin go high?

The Status pin is set high when low‑voltage detection, clock monitor failure, or EPROM parity error occurs, or when the self‑test pin is high.

What is the typical sensitivity of the MMA1200D?

Typical sensitivity is between 1.47 mV/g and 1.72 mV/g depending on supply voltage.