Endress+Hauser Promass 80F/80M/83F/83M User Manual

This document introduces the features and characteristics of a flow meter called Promass, which can simultaneously measure multiple process variables such as mass, density, and temperature. It has a modular design and optional software packages for batch control and concentration measurement. The flow meter also has diagnostic and data backup functions to improve process production quality. It uses an integrated multi-variable flow measurement sensor with strong vibration resistance and robust structure. The flow meter is suitable for measuring liquid and gas flow, and is not affected by the physical properties of the medium. It provides high-precision measurement and meets the requirements of high-quality flow measurement. It has obtained various certifications for explosion-proof and food industry applications. The flow meter is compatible with common process control systems and easy to install.


Endress+Hauser Promass 80F/80M/83F/83M User Manual - cover page
Brand
Proline
Document type
User Manual
Language
Chinese
Pages
64
File format
PDF
File size
2.5 MB
Published
16 December, 2011
Updated
29 September, 2023
Models
80F, 80M, 83F, 83M
MD5 checksum
7723EC038822CC659858530BCCF3C2D6

About this manual

The Promass series (80F, 80M, 83F, 83M) is a universal, multivariable Coriolis mass flow measurement system for liquids and gases. It measures mass flow, density, temperature and can calculate additional variables such as concentration. The sensor design is modular and can be integrated or separated from the transmitter.

The manual provides detailed information on measurement principles, sensor construction, input and output signals, communication interfaces (PROFIBUS PA, MODBUS RS485, FOUNDATION Fieldbus), safety certifications (ATEX, FEM, CSA) and ordering codes. Installation, wiring diagrams and configuration options are also covered. This manual is written in Chinese.

What's inside

  • Measurement Principle
  • System Design
  • Sensor Types
  • Input Signals
  • Output Signals
  • Communication Interfaces
  • Installation and Wiring
  • Safety and Certifications
  • Ordering Information

Specifications

Maximum process pressure350 bar
Maximum medium temperature+350 °C

Frequently asked questions

What is the maximum process pressure rating?

The device can operate at a process pressure of up to 350 bar.

What is the temperature range for the sensor?

The sensor can measure media temperatures up to +350 °C.