This is the list of error codes the ZLG manual gives for the XGate-DPS PROFIBUS-DP slave module. Find your code below and open it for what the manual says about its causes and what to do.
Error codes from p. 17
| Code | Display message | What it means | Page |
|---|---|---|---|
8 |
Invalid parameter | 参数非法 (invalid parameter) | p. 17 |
9 |
Invalid type | 类型非法 (invalid type) | p. 17 |
10~15 |
User‑specified content | 用户指定内容 (user specific) | p. 17 |
0 |
Read constraint conflict | 读限制冲突 (read constrain conflict) | p. 17 |
1 |
Write constraint conflict | 写限制冲突 (write constrain conflict) | p. 17 |
2 |
Resource busy | 资源正忙 (resource busy) | p. 17 |
3 |
Resource unavailable | 资源不存在 (resource unavailable) | p. 17 |
4~7 |
Reserved | 保留 | p. 17 |
8~15 |
User‑specified | 用户指定 (user specific) | p. 17 |
13~15 |
User‑specified | 用户指定 (user specific) | p. 17 |
0x00 |
No further description | 无进一步说明 | p. 18 |
0x01 |
Error occurred, Slot is disturbed (alarm generated by this Slot due to an error) | 出现错误,Slot 受到干扰(由于一个错误该 Slot 产生的报警) | p. 26 |
0x02 |
Error cleared, Slot normal (this Slot generated an alarm indicating no longer any error) | 错误消失,Slot 正常(该 Slot 产生一个报警指示不再有错误) | p. 26 |
0x03 |
Error cleared, but Slot still disturbed (this Slot generated an alarm indicating the error persists) | 错误消失,但 Slot 仍受到干扰(该 Slot 产生一个报警指示不仍有错误) | p. 26 |
01 |
Data part in this module is available, error occurred, e.g., short circuit | 该模块中的数据部可用,发生错误,如短路 | p. 19 |
10 |
Data in this module is invalid due to module insertion error | 因模块插入有错,该模块中的数据无效 | p. 19 |
11 |
Data on this slot is invalid because no module is inserted | 因没有模块插入,故该槽位上的数据无效 | p. 19 |
0x04 |
未分类用户操作类错误类 | p. 26 | |
0x10 |
Ring buffer data overflow | 环形缓冲区数据溢出 | p. 26 |
0x05 |
Invalid time value | 时间值非法 | p. 26 |
0x06 |
Invalid serial port baud rate | 串口波特率非法 | p. 26 |
Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with ZLG. Found a mistake? Report an error.