Yaskawa Varispeed E7 CIMR-E7B Error oPE05: Improper optional part command selection.

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Fault codeoPE05

oPE05 means b1-01 (frequency command selection) is set to 3 (optional card) but the optional card is not connected or the parameter setting value is faulty. The manual's first action is: “Refer to Chapter 7 [Protection, Diagnostic Functions] → [Operation Errors] and make corrections.”

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
Improper optional part command selection. (oPE05)
Type
Fault code
Source
Manual p. 261

What oPE05 means

Improper optional part command selection. p. 264

Common causes

  • Although b1-01 (frequency command selection) is set to 3 (optional card), the optional card (C optional part) is not connected. p. 264
  • Parameter setting value is faulty. p. 264

What to do

  1. Refer to Chapter 7 [Protection, Diagnostic Functions] → [Operation Errors] and make corrections. p. 264

Before you service the product, read the safety instructions in the manual p. 4.

If oPE05 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about oPE05; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.