Yaskawa Varispeed E7 CIMR-E7B Error oPE10: Improper V/f data setting.

Yaskawa Varispeed E7 CIMR-E7B inverter · taken from the manufacturer’s manual, pages cited

Fault codeoPE10

oPE10 means E1-04, 06, 07, 09 do not satisfy the following condition or the parameter setting value is faulty. The manual's first action is: “• E1-04 (FMAX) ≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN)”

Model
Yaskawa Varispeed E7 CIMR-E7B
Display shows
Improper V/f data setting. (oPE10)
Type
Fault code
Source
Manual p. 261

What oPE10 means

Improper V/f data setting. p. 261

Common causes

  • E1-04, 06, 07, 09 do not satisfy the following condition. p. 261
  • Parameter setting value is faulty. p. 261

What to do

  1. • E1-04 (FMAX) ≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN) p. 261
  2. Refer to Chapter 7 [Protection, Diagnostic Functions] → [Operation Errors] and make corrections. p. 261

Before you service the product, read the safety instructions in the manual p. 4.

If oPE10 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about oPE10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.