oPE10 means E1-04, 06, 07, 09 do not satisfy the following condition or the parameter setting value is faulty. The manual's first action is: “• E1-04 (FMAX) ≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN)”
- Model
- Yaskawa Varispeed E7 CIMR-E7B
- Display shows
- Improper V/f data setting. (oPE10)
- Type
- Fault code
- Source
- Manual p. 261
What oPE10 means
Improper V/f data setting. p. 261
Common causes
- E1-04, 06, 07, 09 do not satisfy the following condition. p. 261
- Parameter setting value is faulty. p. 261
What to do
- • E1-04 (FMAX) ≥ E1-06 (FA) > E1-07 (FB) ≥ E1-09 (FMIN) p. 261
- Refer to Chapter 7 [Protection, Diagnostic Functions] → [Operation Errors] and make corrections. p. 261
Before you service the product, read the safety instructions in the manual p. 4.
If oPE10 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.
This page summarises what the manufacturer’s manual says about oPE10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.