Input Under voltage means there is a fault to the equipment at the power side, to the power supply, or the voltage detection circuit at the power side is faulty. The manual's first action is: “Check the wiring of the equipment at the power side.”
- Model
- Yaskawa VARISPEED-656RC5 (CIMR-R5U)
- Display shows
- Input Under voltage (UV)
- Type
- Fault code
- Source
- Manual p. 49
What UV means
Input Under voltage p. 49
Common causes
- There is a fault to the equipment at the power side. p. 49
- There is a fault to the power supply. p. 49
- The voltage detection circuit at the power side is faulty. p. 49
- The regenerative energy from the motor is too large. p. 49
- The power supply voltage is too high. p. 49
- The wiring between the voltage detection circuit at the power side (r1, d1,t1) and the main circuit (R,S,T) is not correct. p. 49
- The wiring distance between the power regenerative unit and the AC reactor is too long. p. 49
- The following conditions occurred during stop. p. 49
What to do
- Check the wiring of the equipment at the power side. p. 49
- Adjust the power supply voltage. p. 49
- Replace the control card. Replace the power board. p. 49
- Adjust the regenerative load. p. 49
- Decrease the voltage so it is within specifications. p. 49
- Check the wiring. p. 49
- Refer to the UV section of the Fault Detection. p. 49
Before you service the product, read the safety instructions in the manual p. 6.
If UV is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.
This page summarises what the manufacturer’s manual says about UV; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.