Yaskawa VARISPEED-656RC5 (CIMR-R5U) Error OH: Heatsink Overheating

Power regenerative unit · taken from the manufacturer’s manual, pages cited

Fault codeOH

Heatsink Overheating means the ambient temperature is too high, there is a heat source nearby, or the power regenerative unit's cooling fan has stopped. The manual's first action is: “Install a cooling unit.”

Model
Yaskawa VARISPEED-656RC5 (CIMR-R5U)
Display shows
Heatsink Overheating (OH)
Type
Fault code
Source
Manual p. 47

What OH means

Heatsink Overheating p. 47

Common causes

  • The ambient temperature is too high. p. 47
  • There is a heat source nearby. p. 47
  • The power regenerative unit's cooling fan has stopped. p. 47
  • The temperature of the power regenerative unit heatsink exceeded 90% of the allowable level. p. 47
  • The power regenerative unit cooling fan has stopped. p. 47

What to do

  1. Install a cooling unit. p. 47
  2. Remove the heat source. p. 47
  3. Replace the cooling fan. (Contact our sales representative.) p. 47
  4. Replace the cooling fan. (Contact your Yaskawa representative.) p. 47

Before you service the product, read the safety instructions in the manual p. 6.

If OH is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Yaskawa service.

This page summarises what the manufacturer’s manual says about OH; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Yaskawa. Found a mistake? Report an error.