A.09 indicates a frequency division setting abnormal when the frequency division setting (Pn212) cannot be set to the specified value (within scale) or exceeds the resolution of the connected encoder, or when a linear motor is connected, a frequency division ratio higher than the maximum ratio derived from the linear motor's maximum speed is set to Pn281. The manual lists no action for this code.
- Model
- YASKAWA SVA-01 / SVB-01
- Display shows
- Frequency division setting abnormal (A.09)
- Type
- Error code
- Source
- Manual p. 472
What A.09 means
Frequency division setting abnormal p. 472
Common causes
- The frequency division setting (Pn212) cannot be set to the specified value (within scale) or exceeds the resolution of the connected encoder. p. 472
- When a linear motor is connected, a frequency division ratio higher than the maximum ratio derived from the linear motor's maximum speed is set to Pn281. p. 472
If A.09 is still not resolved
This page summarises what the manufacturer’s manual says about A.09; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YASKAWA. Found a mistake? Report an error.