E70 indicates undervoltage in the control supply, which occurs when the electronics supply is lower than the minimum value, the electronics power supply has loose contact, or the electronics power supply fuse is blown. The manual's first action is: “Power-on. Reset key. Auto-reset. Dlx.”
- Model
- WEG SSW-07
- Display shows
- Undervoltage in the control supply (E70)
- Type
- Fault code
- Source
- Manual p. 50
What E70 means
Undervoltage in the control supply p. 50
Common causes
- Electronics supply lower than the minimum value. p. 50
- Electronics power supply with loose contact. p. 50
- Electronics power supply fuse blown. p. 50
What to do
- Power-on. Reset key. Auto-reset. Dlx. p. 50
Before you service the product, read the safety instructions in the manual p. 22.
If E70 is still not resolved
- contact the manufacturer or authorized service center p. 6 “Failure to follow these safety instructions may result in personnel injury and/or equipment damage.”
This page summarises what the manufacturer’s manual says about E70; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with WEG. Found a mistake? Report an error.