Vacon NXS/P Error 12: Brake chopper supervision

AC drive · taken from the manufacturer’s manual, pages cited

Fault code12

Brake chopper supervision error happens if there is no brake resistor, a broken resistor, or defective brake chopper. The manual's first action is: “Do a check of the brake resistor and the cabling. If they are in good condition, there is a fault in the resistor or the chopper. Ask instructions from the distributor near to you.”

Model
Vacon NXS/P
Display shows
Brake chopper supervision (12)
Type
Fault code
Source
Manual p. 152

What 12 means

Brake chopper supervision p. 152

Common causes

  • There is no brake resistor. The brake resistor is broken. A defective brake chopper. p. 152

What to do

  1. Do a check of the brake resistor and the cabling. If they are in good condition, there is a fault in the resistor or the chopper. Ask instructions from the distributor near to you. p. 152

Before you service the product, read the safety instructions in the manual p. 13.

If 12 is still not resolved

  • Contact service or dealer for assistance. p. 13
    “WARNING! Before you do electrical work, make sure that there is no voltage in the components of the drive.”
  • Contact service or dealer for assistance. p. 14
    “CAUTION! Do not touch the components on the circuit boards. Static voltage can cause damage to these components.”

This page summarises what the manufacturer’s manual says about 12; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Vacon. Found a mistake? Report an error.