This is the list of error, alarm codes the Siemens manual gives for the TP 170A/TP 170B and OP 170B Siemens TP 170A/TP 170B and OP 170B touch panel. Find your code below and open it for what the manual says about its causes and what to do.
Error codes from p. 155
| Code | Display message | What it means | Page |
|---|---|---|---|
290025 |
Confirmation that the data record download from PLC to the operator unit was terminated due to an error. | 确认数据记录从 PLC 到操作单元的下载由于出错而被终止。 | p. 155 |
290026 |
Attempted to read/write a data record while the data mailbox is not free. This can occur when a synchronous download has already been configured for a recipe. | 尝试读/写数据记录,尽管目前数据信箱不空闲。这可能发生在已经为配方组态了同步下载的情况下。 | p. 155 |
290027 |
目前不能与 PLC 建立连接。因此,既不能读取数据记录,也不能写入数据记录。可能原因:没有与 PLC 进行物理连接(没有插入任何电缆、电缆是坏的)或 PLC 已关闭。 | p. 155 | |
290030 |
This message appears after re-selecting a screen that displays a recipe (where a data record has already been selected). | 在重新选择一个包含有配方显示的画面(在其中已经选择了数据记录)之后,出现该消息。 | p. 155 |
290031 |
During the save operation, a data record with the specified number was found to already exist. | 在保存过程中,检测到具有指定编号的数据记录已存在。 | p. 155 |
290032 |
When exporting a data record, a file with the specified name was found to already exist. | 在导出数据记录时,检测到具有指定名称的文件已存在。 | p. 155 |
290033 |
Confirmation is required before deleting a data record. | 在删除数据记录之前,对请求进行确认。 | p. 155 |
290041 |
The data record or file cannot be saved because the data medium is full. | 数据记录或文件不能保存,因为数据介质已满。 | p. 155 |
290042 |
Attempted to execute multiple download/store functions simultaneously. The previous action was not performed. | 尝试同时执行多个下载/存储功能。没有执行上一个动作。 | p. 155 |
290052 |
Confirmation that the export of the data record was terminated due to an error. | 确认数据记录的导出由于出错已终止。 | p. 155 |
290055 |
Confirmation that the import of the data record was terminated due to an error. | 确认数据记录的导入由于出错已终止。 | p. 155 |
290056 |
The value in the specified row/column could not be read or written without error. The action has been canceled. | 所指定行/列中的数值不能没有错误地读取或写入。该动作取消。 | p. 155 |
310000 |
Too many protocols were attempted to be printed simultaneously. Because only one protocol can be printed at a time, the print job was rejected. | 尝试同时打印的协议太多。因为一次只能打印一个协议,所以打印作业被拒绝。 | p. 155 |
310001 |
An error occurred while triggering the printer. The protocol could not be printed or an error occurred during printing. | 在触发打印机期间发生错误。协议不能打印或打印时出错。 | p. 156 |
320000 |
The move is being displayed by another device. The move cannot be controlled by the operator. | 移动已由另一个设备显示。移动不能由操作员控制。 | p. 156 |
320003 |
The PLC cannot read the required signal status. The error operator cannot be determined. | PLC 不能读取必要的信号状态。不能确定错误操作符。 | p. 156 |
320004 |
The project contains ProAgent components that have not been installed. ProAgent process diagnostics cannot be performed. | 项目包含还没有安装的 ProAgent 组件。不能执行 ProAgent 过程诊断。 | p. 156 |
Alarm codes from p. 155
| Code | Display message | What it means | Page |
|---|---|---|---|
300000 |
过程监控(例如使用 PDiag 或 S7-Graph)已被错误编程。同时显示比在与 CPU 相关的技术数据中所指定的消息更多的消息。CPU 不能管理后面的 Alarm_S 消息,并将其传送给操作单元。 | p. 155 | |
320001 |
The network is too complex. The error operator cannot be displayed. | 网络太复杂。错误操作符不能显示。 | p. 156 |
320002 |
Multiple or no diagnosable alarm messages have been selected. The unit associated with the alarm message cannot be selected. There are no alarm messages for the unit selected by the user. The network cannot be displayed in the detailed view. | 已选择多个或未选择可诊断的报警消息。不能选择与报警消息相关的单元。对于用户所选择的单元,没有报警消息。在详细显示中不能显示网络。 | p. 156 |
Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.