Siemens SINAMICS V90, SIMOTICS S-1FL6 Error A1902: PROFIdrive: Clock cycle synchronous operation parameterization not permissible

Industrial motor drive · taken from the manufacturer’s manual, pages cited

Fault codeA1902

Parameterization for isochronous operation is not permissible. The manual's first action is: “Adapt the bus parameterization Tdp, Ti, To.”

Model
Siemens SINAMICS V90, SIMOTICS S-1FL6
Display shows
A1902
Type
Fault code
Source
Manual p. 305

What A1902 means

PROFIdrive: Clock cycle synchronous operation parameterization not permissible p. 305

Common causes

  • Parameterization for isochronous operation is not permissible. p. 305

Safety warnings — read before you start

  • DANGERGeneral Safety Instructions. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. p. 2
  • WARNINGRisk of Electric Shock and Fire. Risk of electric shock and fire from supply networks with an excessively low impedance Excessively high short-circuit currents can lead to the protective devices not being able to interrupt these short-circuit currents and being destroyed, and thus causing electric shock or a fire. p. 12
  • WARNINGElectric Shock if No Ground Connection. Electric shock if there is no ground connection For missing or incorrectly implemented protective conductor connection for devices with protection class I, high voltages can be present at open, exposed parts, which when touched, can result in death or severe injury. p. 12
  • WARNINGElectric Shock Due to Unsuitable Power Supply. Electric shock due to connection to an unsuitable power supply When equipment is connected to an unsuitable power supply, exposed components may carry a hazardous voltage that might result in serious injury or death. p. 12

What to do

  1. Adapt the bus parameterization Tdp, Ti, To. p. 305
  2. Adapt the sampling time for the current controller or speed controller. p. 305
  3. Reduce Tdx by using fewer bus participants or shorter telegrams. p. 305

If A1902 is still not resolved

  • Contact service / dealer for assistance p. 2
    “Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions.”
  • Contact service / dealer for assistance p. 13
    “NOTICE Property damage due to loose power connections Insufficient tightening torques or vibration can result in loose power connections. This can result in damage due to fire, device defects or malfunctions.”

This page summarises what the manufacturer’s manual says about A1902; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.