Siemens MICROMASTER 430 Error A0952: Drive belt fault detected

Siemens MICROMASTER 430 · taken from the manufacturer’s manual, pages cited

Fault codeA0952

The A0952 code means a drive belt fault or mechanical fault is detected. The manual's first action is: “Check the following: 1. The drive's transmission system for any breaks, jams, or blockages. 2. Any external speed sensor (if speed feedback is used) must operate correctly. The values of P0409 (pulses per minute at rated speed), P2191 (feedback frequency deviation), and P2192 (delay time corresponding to allowed deviation) must be correct. 3. If torque control is used, verify that the following parameters are correct: P2182 (frequency threshold F1), P2183 (frequency threshold F2), P2184 (frequency threshold F3), P2185 (torque upper limit 1), P2186 (torque lower limit 1), P2187 (torque upper limit 2), P2188 (torque lower limit 2), P2189 (torque upper limit 3), P2190 (torque lower limit 3), and P2192 (delay time corresponding to allowed deviation). 4. Add lubrication if necessary.”

Model
Siemens MICROMASTER 430
Display shows
Drive belt fault detected (A0952)
Type
Fault code
Source
Manual p. 91

What A0952 means

Drive belt fault detected p. 91

Common causes

  • The motor load condition indicates a belt fault or mechanical fault. p. 91

What to do

  1. Check the following: 1. The drive's transmission system for any breaks, jams, or blockages. 2. Any external speed sensor (if speed feedback is used) must operate correctly. The values of P0409 (pulses per minute at rated speed), P2191 (feedback frequency deviation), and P2192 (delay time corresponding to allowed deviation) must be correct. 3. If torque control is used, verify that the following parameters are correct: P2182 (frequency threshold F1), P2183 (frequency threshold F2), P2184 (frequency threshold F3), P2185 (torque upper limit 1), P2186 (torque lower limit 1), P2187 (torque upper limit 2), P2188 (torque lower limit 2), P2189 (torque upper limit 3), P2190 (torque lower limit 3), and P2192 (delay time corresponding to allowed deviation). 4. Add lubrication if necessary. p. 91

Before you service the product, read the safety instructions in the manual p. 7.

If A0952 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about A0952; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.