Fault codeF01659
Denial of paramet. change means the drive failed to finalize safety parameters, due to incorrect password or tolerance settings. The manual lists no action for this code.
- Model
- Siemens CU240S
- Display shows
- Denial of paramet. change (F01659)
- Type
- Fault code
- Source
- Manual p. 403
What F01659 means
Denial of paramet. change p. 403
Common causes
- r0949 = 0: Problem during finalization of safety parameters. Drive has reloaded the old data. p. 403
- r0949 = 1: Safety password not set correctly. p. 403
- r0949 = 3: Tolerance too small (p9891 < p9890). Increase tolerance! p. 403
- r0949 = 203: Tolerance too small (p9891 < p9890). Increase tolerance! p. 403
If F01659 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.
This page summarises what the manufacturer’s manual says about F01659; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.