Siemens 6SE6400-5AB00-0BP0 Error F0001: Overcurrent

Siemens MICROMASTER 420 Inverter · taken from the manufacturer’s manual, pages cited

Error codeF0001

Code F0001 indicates overcurrent due to rise time setting too short or voltage increase too fast. The manual's first action is: “Correspondingly increase the value of P1120.”

Model
Siemens 6SE6400-5AB00-0BP0
Display shows
Overcurrent (F0001)
Type
Error code
Source
Manual p. 13

What F0001 means

Overcurrent p. 13

Common causes

  • Rise time setting too short p. 13
  • Voltage increase too fast p. 13

What to do

  1. Correspondingly increase the value of P1120. p. 13
  2. Decrease the values of parameters P1310, P1311, and P1312 to prevent excessive motor magnetization. p. 13

Before you service the product, read the safety instructions in the manual p. 2.

If F0001 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Siemens service.

This page summarises what the manufacturer’s manual says about F0001; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Siemens. Found a mistake? Report an error.