Schneider Electric ATV 21 Error OL3: OL3

Schneider Electric ATV 21 Frequency Transformer · taken from the manufacturer’s manual, pages cited

Error codeOL3

The OL3 indicates a sudden load change, load is in standby, or the frequency control mode selection parameter F3 is improperly set. The manual's first action is: “Reduce load fluctuations.”

Model
Schneider Electric ATV 21
Display shows
OL3 (OL3)
Type
Error code
Source
Manual p. 233

What OL3 means

OL3 p. 233

Common causes

  • Sudden load change. p. 233
  • Load is in standby. p. 233
  • Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233

What to do

  1. Reduce load fluctuations. p. 233
  2. Reduce load (operating machine). p. 233
  3. Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233

Before you service the product, read the safety instructions in the manual p. 8.

If OL3 is still not resolved

  • Contact local sales agent for parts replacement. p. 7
    “如要更换零件,请致电当地的销售代理处”
  • Perform daily equipment inspection. p. 7
    “应每天对设备进行检查”

This page summarises what the manufacturer’s manual says about OL3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.