Schneider Electric ATV 21 Error OL2: OL2

Schneider Electric ATV 21 Frequency Transformer · taken from the manufacturer’s manual, pages cited

Fault codeOL2

The OL2 indicates jump time dEC is too short, frequency control mode selection parameter F3 is improperly set, or the motor is overloaded. The manual's first action is: “Increase jump time dEC.”

Model
Schneider Electric ATV 21
Display shows
OL2 (OL2)
Type
Fault code
Source
Manual p. 233

What OL2 means

OL2 p. 233

Common causes

  • Jump time dEC is too short. p. 233
  • Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233
  • Motor overload. p. 233
  • Motor fault. p. 233
  • Continuous low‑speed operation. p. 233
  • Excessive load applied to motor during operation. p. 233
  • Check system errors. p. 233

What to do

  1. Increase jump time dEC. p. 233
  2. Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233
  3. Check V/F parameter settings. p. 233
  4. Check the load (operating machine). p. 233
  5. Reduce OL1 to an overload value the motor can tolerate in the low‑speed range. p. 233
  6. Enable F6.15 (over‑torque limit selection). p. 233

Before you service the product, read the safety instructions in the manual p. 8.

If OL2 is still not resolved

  • Contact local sales agent for parts replacement. p. 7
    “如要更换零件,请致电当地的销售代理处”
  • Perform daily equipment inspection. p. 7
    “应每天对设备进行检查”

This page summarises what the manufacturer’s manual says about OL2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.