Fault codeOL2
The OL2 indicates jump time dEC is too short, frequency control mode selection parameter F3 is improperly set, or the motor is overloaded. The manual's first action is: “Increase jump time dEC.”
- Model
- Schneider Electric ATV 21
- Display shows
- OL2 (OL2)
- Type
- Fault code
- Source
- Manual p. 233
What OL2 means
OL2 p. 233
Common causes
- Jump time dEC is too short. p. 233
- Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233
- Motor overload. p. 233
- Motor fault. p. 233
- Continuous low‑speed operation. p. 233
- Excessive load applied to motor during operation. p. 233
- Check system errors. p. 233
What to do
- Increase jump time dEC. p. 233
- Adjust frequency control mode selection parameter F3 (set parameter 6 to 1 or 3 for automatic frequency reduction). p. 233
- Check V/F parameter settings. p. 233
- Check the load (operating machine). p. 233
- Reduce OL1 to an overload value the motor can tolerate in the low‑speed range. p. 233
- Enable F6.15 (over‑torque limit selection). p. 233
Before you service the product, read the safety instructions in the manual p. 8.
If OL2 is still not resolved
This page summarises what the manufacturer’s manual says about OL2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.