Schneider Electric Altivar 71 Error brF: [Brake feedback]

Schneider Electric Altivar 71 · taken from the manufacturer’s manual, pages cited

Fault codebrF

The brake feedback contact does not match the brake logic control indicates a mismatch between brake feedback and brake logic control. The manual's first action is: “Check the feedback circuit and the brake logic control circuit Check the mechanical state of the brake Check the brake linings”

Model
Schneider Electric Altivar 71
Display shows
[Brake feedback] (brF)
Type
Fault code
Source
Manual p. 287

What brF means

[Brake feedback] p. 287

Common causes

  • The brake feedback contact does not match the brake logic control p. 287
  • The brake does not stop the motor quickly enough (detected by measuring the speed on the "Pulse input" input). p. 287

What to do

  1. Check the feedback circuit and the brake logic control circuit Check the mechanical state of the brake Check the brake linings p. 287

Before you service the product, read the safety instructions in the manual p. 16.

If brF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about brF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.