Fault codeSOF
There is instability or the driving load is too high. The manual's first action is: “Check the motor, gain and stability parameters Add a braking resistor Check the size of the motor/drive/load”
- Model
- Schneider Electric Altivar 61W
- Display shows
- [Overspeed] (SOF)
- Type
- Fault code
- Source
- Manual p. 76
What SOF means
[Overspeed] p. 76
Common causes
- Instability or driving load too high p. 76
What to do
- Check the motor, gain and stability parameters Add a braking resistor Check the size of the motor/drive/load p. 76
Before you service the product, read the safety instructions in the manual p. 43.
If SOF is still not resolved
- Disconnect all power including external control power p. 44 “Disconnect all power including external control power that may be present before servicing the drive.”
This page summarises what the manufacturer’s manual says about SOF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.