Schneider Electric Altivar 61W Error PrtF: [Power Ident]

Altivar 61W drive · taken from the manufacturer’s manual, pages cited

Fault codePrtF

Power Ident indicates that the [Power Identification] (Prt) parameter is incorrect or a control card has been replaced with one configured for a drive with a different rating. The manual's first action is: “Enter the correct parameter (reserved for Schneider Electric product support)”

Model
Schneider Electric Altivar 61W
Display shows
[Power Ident] (PrtF)
Type
Fault code
Source
Manual p. 79

What PrtF means

[Power Ident] p. 79

Common causes

  • The [Power Identification] (Prt) parameter is incorrect p. 79
  • Control card replaced by a control card configured on a drive with a different rating p. 79

What to do

  1. Enter the correct parameter (reserved for Schneider Electric product support) p. 79
  2. Check that there are no card errors In the event of the control card being changed deliberately, consult the CD-ROM supplied with the drive p. 79

Before you service the product, read the safety instructions in the manual p. 43.

If PrtF is still not resolved

  • Disconnect all power including external control power p. 44
    “Disconnect all power including external control power that may be present before servicing the drive.”

This page summarises what the manufacturer’s manual says about PrtF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.