Schneider Electric Altistart 48 Error SLF: Serial link fault

Altistart 48 soft starter · taken from the manufacturer’s manual, pages cited

Fault codeSLF

Serial link fault means the RS485 connection has an issue. The manual's first action is: “Check the RS485 connection.”

Model
Schneider Electric Altistart 48
Display shows
Serial link fault (SLF)
Type
Fault code
Source
Manual p. 160

What SLF means

Serial link fault p. 160

Common causes

  • Check the mechanism (wear, mechanical play, lubrication, blockages, etc.) p. 160

What to do

  1. Check the RS485 connection. p. 160
  2. Check the value of the tLS setting in the PrO menu page 135. p. 160
  3. Check the sizing of the starter-motor in relation to the mechanical requirement. p. 160
  4. Check the value of the thP parameter in the PrO menu page 135 and that of the In parameter in the SET menu page 130. p. 160
  5. Check the electrical isolation of the motor. p. 160
  6. Wait for the motor to cool before restarting. p. 160

If SLF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Schneider Electric service.

This page summarises what the manufacturer’s manual says about SLF; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Schneider Electric. Found a mistake? Report an error.