IC ERROR happens due to communication integrated circuit malfunction or RS485 cable noise interference. The manual's first action is: “Check the connection of the RS485 cables. Replace the cable if the trouble occurs after confirming the connection.”
- Model
- Sanyo Machine Works SDNR
- Display shows
- IC ERROR (B3)
- Type
- Error code
- Source
- Manual p. 104
What B3 means
IC ERROR p. 130
Common causes
- The aberration of the communication integrated circuit. p. 130
- The aberration of the RS485 cable by noise etc. p. 130
What to do
- Check the connection of the RS485 cables. Replace the cable if the trouble occurs after confirming the connection. p. 130
- Inform us about the environment (power noise or another noise source, etc) around the NUTRUNNER system. p. 130
Before you service the product, read the safety instructions in the manual p. 65.
If B3 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.
This page summarises what the manufacturer’s manual says about B3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.