Error code54
MID. POINT TORQUE MINIMUM TROUBLE means the torque at the mid-point judgment is below the minimum acceptable value. The manual lists no action for this code.
- Model
- Sanyo Machine Works SDNR
- Display shows
- MID. POINT TORQUE MINIMUM TROUBLE (54)
- Type
- Error code
- Source
- Manual p. 103
What 54 means
MID. POINT TORQUE MINIMUM TROUBLE p. 103
Common causes
- MID. POINT TORQUE MINIMUM TROUBLE occurs, when the torque of the point which fastened MID POINT JUDGEMENT ANGLE from MID POINT JUDGEMENT TORQUE is smaller than MID POINT TORQUE MINIMUM. p. 103
If 54 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Sanyo Machine Works service.
This page summarises what the manufacturer’s manual says about 54; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Sanyo Machine Works. Found a mistake? Report an error.