Overtravel inhibit means both the CW and CCW over-travel limits are not active. The manual's first action is: “Check the switches, wires and power supply that constitute the circuits. Check that the control power (12 to 24VDC) can be established without delay. Check the value of Pr04. Correct the wiring, if necessary.”
- Model
- Panasonic MINAS A-series
- Display shows
- Overtravel inhibit (38)
- Type
- Error code
- Source
- Manual p. 69
What 38 means
Overtravel inhibit p. 69
Common causes
- Both the CW and CCW over-travel limits are not active. p. 69
What to do
- Check the switches, wires and power supply that constitute the circuits. Check that the control power (12 to 24VDC) can be established without delay. Check the value of Pr04. Correct the wiring, if necessary. p. 69
Before you service the product, read the safety instructions in the manual p. 4.
If 38 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.
This page summarises what the manufacturer’s manual says about 38; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.