Command pulse scale error means the command pulse is larger than 500 kpps at the entrance of the position error counter or the scale ratios set by Pr46 through Pr4B are not correct. The manual's first action is: “Reduce the multiplication factor by adjusting the values of Pr46 through Pr4B, and then adjust the scale ratios so that the command pulse frequency is 500 kpps or less.”
- Model
- Panasonic MINAS A-series
- Display shows
- Command pulse scale error (27)
- Type
- Error code
- Source
- Manual p. 69
What 27 means
Command pulse scale error p. 69
Common causes
- The command pulse is larger than 500 kpps at the entrance of the position error counter. The scale ratios set by Pr46 through Pr4B (numerator of 1st to 4th command scale) are not correct. p. 69
What to do
- Reduce the multiplication factor by adjusting the values of Pr46 through Pr4B, and then adjust the scale ratios so that the command pulse frequency is 500 kpps or less. p. 69
Before you service the product, read the safety instructions in the manual p. 4.
If 27 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.
This page summarises what the manufacturer’s manual says about 27; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.