Panasonic MINAS A-series Error 29: Error counter overflow

Servo motor driver · taken from the manufacturer’s manual, pages cited

Error code29

Error counter overflow means the value of the position error counter is over 227 (134217728). The manual's first action is: “Check that the motor operates per the position command pulse. See the torque monitor to check that the output torque does not get saturated. Readjust the gains. Maximize the value of Pr5E (torque limit set-up). Correct the encoder wiring per the wiring diagram.”

Model
Panasonic MINAS A-series
Display shows
Error counter overflow (29)
Type
Error code
Source
Manual p. 69

What 29 means

Error counter overflow p. 69

Common causes

  • The value of the position error counter is over 227 (134217728). p. 69

What to do

  1. Check that the motor operates per the position command pulse. See the torque monitor to check that the output torque does not get saturated. Readjust the gains. Maximize the value of Pr5E (torque limit set-up). Correct the encoder wiring per the wiring diagram. p. 69

Before you service the product, read the safety instructions in the manual p. 4.

If 29 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Panasonic service.

This page summarises what the manufacturer’s manual says about 29; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Panasonic. Found a mistake? Report an error.