Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The auto start separation motor does not rotate due to a faulty auto start crescent sensor or auto start separation clock. The manual's first action is: “See the ADF Service Manual.”
The sensor level is faulty. The manual's first action is: “See the ADF Service Manual.”
The delivery motor does not rotate because the delivery clock is faulty. The manual's first action is: “See the ADF Service Manual.”
The feed motor does not rotate because the feed motor clock is faulty. The manual's first action is: “See the ADF Service Manual.”
The belt motor does not rotate because the belt clock is faulty. The manual's first action is: “See the ADF Service Manual.”
The separation motor does not rotate because the crescent sensor is faulty. The manual's first action is: “See the ADF Service Manual.”
Communication with the copier has failed due to an interruption in data exchange between devices. The manual's first action is: “The communication is monitored at all times. This error occurs when the communication wi…
The ozone filter or cleaner thermistor (TH3) or DC controller PCB is malfunctioning, leading to an error related to air purification or sensor failure. The manual's first action is: “Replace the ozone filter. Is the p…
An exhaust fan (FM2, FM4, FM5) or connector or DC controller PCB is faulty, causing a ventilation error that requires checking service mode '106'. The manual's first action is: “Check service mode '106' (E805 details)…
The power supply PCB or DC controller PCB is malfunctioning, resulting in general system failure. The manual's first action is: “Turn off and then on the power switch. Is the problem corrected?”
The power supply frequency is faulty, leading to an error indicating a problem with the electrical input. The manual's first action is: “End.”
The lamp regulator PCB or DC controller PCB is malfunctioning, causing the scanning lamp to fail to turn on. The manual's first action is: “See "The scanning lamp fails to turn on."”
The lens home position sensor (PS2) is faulty, preventing proper lens positioning during scanning. The manual's first action is: “Check the wiring from the DC controller PCB to the sensor; if normal, replace the sensor.”
The mirror home position sensor (PS3) is faulty, causing the mirror to not respond correctly to its position. The manual's first action is: “Check the wiring from the DC controller PCB to the sensor; if normal, replac…
The keys on the control panel fail to operate due to a faulty scanner home position sensor (PS1) or DC controller PCB. The manual's first action is: “See "The scanner fails to move."”