Error, fault and alarm codes of products - what each code means, its causes and what to do - read from the manufacturers’ manuals, with the manual page each answer comes from.
The macro job execution has failed due to incorrect settings. The manual's first action is: “(1)Check the following settings. -Check the settings for execution macro job.”
A software operation error occurred that lacks global variable area. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then…
A setting error has occurred in the tool data configuration. The manual's first action is: “(1)Check the following settings. -Correct the job so that the setting value of tag is allowable value. -Set the allowance amo…
The system detected a setting error related to home position correction data. The manual's first action is: “(1)Check the following settings. -Registration for the home position correction data.”
A software operation error has occurred in the servo system. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact…
A software operation error occurred in servo float mode. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact you…
The system detected undefined press resolution data. The manual's first action is: “(1)Check the following settings. -Set the press resolution data to be used in the job.”
The system detected an undefined press characteristic data file. The manual's first action is: “(1)Check the following settings. -Set the status of press characteristic file to be used in the job to "Used State".”
The system cannot monitor distance due to a setting error. The manual's first action is: “(1)Check the following settings. -Change the interpolation instruction to MCVL/MOV C. -Change the setting so that the arc retry…
The teaching points are incorrect. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa representati…
A software operation error has occurred. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then contact your Yaskawa repres…
A software operation error has occurred due to mismatched software. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mode, and then …
The system cannot execute an instruction because it is set in a system job instead of a user job. The manual's first action is: “(1)Check the following settings. The instruction cannot be executed in the system job. C…
The system detected an error in executing an INIEVNT instruction. The manual's first action is: “(1)Check the following settings. -Execute an INIEVNT instruction before executing an event related instruction.”
The system cannot perform the specified event due to a software operation error. The manual's first action is: “(1)Reset the alarm, and then try again. (2)If the alarm occurs again, save the CMOS BIN in maintenance mo…