All 5 error codes of the Canon EOS REBEL T3i/EOS 600D Canon EOS REBEL T3i/EOS 600D with their meaning, causes and what to do, taken from the manufacturer's manual with page references.
System errors due to electromagnetic interference or poor earth connection. The manual lists no action for this code.
The motor is incorrectly connected as star or delta. The manual's first action is: “Check preset motor data (P201...P209)”
The inverter failed to identify the connected motor automatically. The manual's first action is: “Check motor connection”
The safety circuit has tripped while the inverter was enabled. The manual lists no action for this code.
Motor current control response during brake operation failure The manual's first action is: “Check setting of P539”
Motor phase error indicates one of the motor phases is not connected. The manual's first action is: “Check setting of P539”
The motor can no longer ensure the setpoint due to reaching the contouring error limit. The manual's first action is: “Set a higher torque limit value / current limit in P112/P536.”
The system detected an error in speed contouring. The manual lists no action for this code.
The speed contouring error limit has been reached. The manual's first action is: “Set a higher value in P327.”
The watchdog function detected no "high edge" signal on a digital input within the set time interval. The manual lists no action for this code.
The customer interface reference voltage is incorrect at 10V or 15V. The manual's first action is: “Check control terminals for short-circuit fault.”
Telegram time-out error indicates failed transmission of telegrams over external buses. The manual lists no action for this code.
ControlBox error indicates communication fault on the SPI bus or incorrect installation. The manual's first action is: “Check whether the ControlBox has been fitted correctly as specified.”
EEPROM trouble caused parameters to be lost and reset to factory settings The manual's first action is: “Software version of the stored data record does not match the software version of the inverter.”