PAR PFC IO 2 indicates mismatch between number of PFC motors and configured relay outputs. The manual lists no action for this code.
PAR PFC IO 1 indicates incomplete I/O configuration for PFC with relay conflicts. The manual lists no action for this code.
PAR PCU 1 indicates inconsistent power control parameters due to improper motor nominal frequency or speed. The manual's first action is: “Check for both of the following: • 1 ≤ (60 · 9907 MOTOR NOM FREQ / 9908 MOTOR …
PAR PFC MODE indicates an inconsistency in power factor correction mode settings. The manual lists no action for this code.
PAR FIELDBUS MISSING indicates a missing fieldbus connection when fieldbus control is enabled. The manual's first action is: “Check for and correct: • A parameter is set to fieldbus control (e.g. 1001 EXT1 COMMANDS = …
PAR EXT RO indicates inconsistent parameter values related to extension relay module configuration. The manual's first action is: “Check for the following: • Extension relay module not connected and • 1410...1412 RELA…
PAR PCU 2 indicates inconsistent power control parameters due to improper motor nominal kVA or power. The manual's first action is: “Check for the following: • 1.1 ≤ (9906 MOTOR NOM CURR · 9905 MOTOR NOM VOLT · 1.73 /…
PAR AO SCALE indicates inconsistent parameter values for analog output scaling. The manual's first action is: “Check for any of the following: • 1504 MINIMUM AO1 > 1505 MAXIMUM AO1. • 1510 MINIMUM AO2 > 1511 MAXIMUM A…
PAR AI SCALE indicates inconsistent parameter values for analog input scaling. The manual's first action is: “Check for any of the following: • 1301 MINIMUM A1 > 1302 MAXIMUM A1. • 1304 MINIMUM A2 > 1305 MAXIMUM A2.”
Reserved (obsolete) is an obsolete code with no current meaning. The manual lists no action for this code.
PAR PFC REF NEG indicates a negative reference value when PFC is enabled. The manual's first action is: “Check for the following: • 2007 MINIMUM FREQ is negative, when 8123 PFC ENABLE is active.”
PAR HZRP M indicates inconsistent parameter values related to frequency and speed settings. The manual's first action is: “Check for any of the following: • 2001 MINIMUM SPEED > 2002 MAXIMUM SPEED. • 2007 MINIMUM FREQ…
EFB LOAD ERROR indicates a load error in the EFB system. The manual lists no action for this code.
CB ID ERROR indicates an identification error for the circuit breaker. The manual lists no action for this code.
Reserved (obsolete) is an obsolete code with no current meaning. The manual lists no action for this code.