COMMUNICATION TROUBLE happens due to faulty RS485 cable or connection, or interference from noise. The manual's first action is: “Check the connection of the RS485 cables. Replace the cable if the trouble occurs after…
COMMUNICATION RECEPTION ERROR occurs when the RS485 cable or its connection is wrong or affected by noise. The manual's first action is: “Check the connection of the RS485 cables. Replace the cable if the trouble occu…
IC ERROR happens due to communication integrated circuit malfunction or RS485 cable noise interference. The manual's first action is: “Check the connection of the RS485 cables. Replace the cable if the trouble occurs …
DOUBLE ID ERROR occurs when the DIP switch setting is incorrect, multiple DISPLAY PANELS are connected, or the RS485 cable is improperly connected. The manual's first action is: “Correct the NUTRUNNER ID setting of th…
There is a format error caused by aberration in the communication integrated circuit or RS485 cable affected by noise. The manual's first action is: “Inform us about the environment (power noise or another noise sourc…
The CPU is alarmed due to interference from noise conditions affecting its operation. The manual's first action is: “Contact our company.”
The sum check has failed, likely due to interrupted writing or noise affecting NUTRUNNER settings. The manual's first action is: “Rewrite the settings to the NUTRUNNER. If the trouble still occurs after re-writing, co…
The parameter selection is incorrect because of improper parameter settings. The manual's first action is: “Set a correct parameter in selection command.”
There is a jump command error in the fastening program due to wrong system settings. The manual's first action is: “Confirm jump command of fastening program.”
There is an error in the program code due to incorrect system settings. The manual's first action is: “Confirm command code of fastening program.”
The program has ended unexpectedly due to an incorrect system setting. The manual's first action is: “Add an end of cycle command to the end of the fastening program.”
The motor type setting is incorrect because of a wrong DIP switch (DSW2) configuration. The manual's first action is: “Correct the NUTRUNNER model setting of the DRIVER'S DIP switch (DSW 2).”
The T/T type setting is incorrect due to wrong system settings or DIP switch (DSW2) configuration, or RS485 cable connection issues. The manual's first action is: “Correct the NUTRUNNER model setting of the DRIVER'S D…
There is a calibration error in the T/T system. The manual lists no action for this code.
There is an offset error in the T/T system. The manual lists no action for this code.