ID ERROR occurs due to incorrect system settings or a DIP switch (DSW2) configuration. The manual's first action is: “Correct the settings of the DRIVER's DIP switch (DSW2) or EEPROM.”
MOTOR TYPE ERROR occurs due to incorrect system settings or a DIP switch (DSW2) configuration. The manual's first action is: “Correct the settings of the DRIVER's DIP switch (DSW2) or EEPROM.”
T/T TYPE ERROR occurs due to incorrect system settings or a DIP switch (DSW2) configuration. The manual's first action is: “Correct the settings of the DRIVER's DIP switch (DSW2) or EEPROM.”
UIT/PR PORT TRANSMISSION ERROR occurs when the communication cable or its connection is wrong, the protocol is incorrect, or transmission timing is too early. The manual's first action is: “Check the connection of the…
UIT/PR PORT ERROR occurs when the communication cable or its connection is wrong, the protocol is incorrect, or transmission timing is too early. The manual's first action is: “Check the connection of the communicatio…
RS232C PORT TRANSMISSION ERROR occurs when the communication cable or its connection is wrong, or the reception process is too slow. The manual's first action is: “Check the connection of the communication cable. Repl…
RS232C PORT ERROR occurs when the communication cable or its connection is wrong, the protocol is incorrect, or transmission timing is too early. The manual's first action is: “Check the connection of the communicatio…
RECEPTION TROUBLE is listed without a specific cause in this product's manual. The manual lists no action for this code.
COMMUNICATION TROUBLE is listed without a specific cause in this product's manual. The manual lists no action for this code.
COMMUNICATION RECEPTION ERROR occurs when the RS485 cable or its connection is wrong, or noise affects the RS485 cable. The manual's first action is: “Check the connection of the RS485 cables. Replace the cable if the…
IC ERROR happens due to aberration in the communication integrated circuit or noise affecting the RS485 cable. The manual's first action is: “Replace the MULTI CONTROLLER.”
DOUBLE ID ERROR occurs when the DIP switch (DSW1) is wrong, multiple DISPLAY PANELS are connected, or the RS485 cable or its connection is wrong. The manual's first action is: “Correct the setting of the DRIVER's DIP …
RECONFIGURATION ERROR occurs when power was interrupted or RS485 cables are damaged due to noise or improper connection. The manual's first action is: “Check the power source of DRIVER and DISPLAY PANEL.”
FORMAT ERROR indicates an aberration in the format of the MULTI CONTROLLER. The manual's first action is: “Replace the MULTI CONTROLLER.”
TOKEN ERROR occurs due to wrong RS485 cable connection or power not supplied to the DRIVER. The manual's first action is: “Check the connection of RS485 cables. Replace the cable if the trouble occurs after confirming…