Omron WS02-PSTC1-E Error Codes

52 codes from pages 125–375 of the manual

This is the list of error codes the Omron manual gives for the WS02-PSTC1-E CX-Protocol Operation Manual. Find your code below and open it for what the manual says about its causes and what to do.

Error codes from p. 178

CodeWhat it meansPage
0 Protocol macro (sequence) abnormal execution p. 178
2 Sequence No. error p. 178
3 Data read/Data write area exceeded error p. 178
4 Protocol data syntax error p. 178
its 00 Sequence number designated in C2 of PMCR instruction is set to a value other than 000 to 3E7 hexadecimal (000 to 999 decimal). Communications sequence number that does not exist in the protocol data is designated. p. 207
its 01 Sequence number designated in C2 of PMCR instruction is set to a value other than 000 to 3E7 hexadecimal (000 to 999 decimal). Communications sequence number that does not exist in the protocol data is designated. p. 207
its 02 Sequence number designated in C2 of PMCR instruction is set to a value other than 000 to 3E7 hexadecimal (000 to 999 decimal). Communications sequence number that does not exist in the protocol data is designated. p. 207
its 03 Sequence number designated in C2 of PMCR instruction is set to a value other than 000 to 3E7 hexadecimal (000 to 999 decimal). Communications sequence number that does not exist in the protocol data is designated. p. 207
A Aborting compare. PMSU is not valid for any of the selected protocols. p. 361
C Can not select O1 or O2 when variable type is write. p. 361
U Unable to complete protocol compare. p. 366
W Warning ... ? ... The selected PLC does not support the Protocol Macro function. Connection to the device from CX-Protocol will not be allowed. p. 366
E1001 ... Total Link Channels out of range... p. 366
E1005 No data in message. p. 366
E1006 Check code after Terminator not supported on this unit. p. 366
E1007 Check code ~LRC not supported on this unit. p. 366
E1008 Check code ~CCITT not supported on this unit. p. 366
E1009 Check code CRC16 not supported on this unit. p. 366
E1010 Check code ~SUM (1 byte) not supported on this unit. p. 366
E1011 Check code ~SUM (2 bytes) not supported on this unit. p. 366
E1012 Check code SUM (1 byte) not supported on this unit. p. 366
E1013 Check code SUM2 (2 bytes) not supported on this unit. p. 367
E1014 Overlap in sequence range with protocol... p. 367
E1022 Communication Sequence contains no step data. p. 367
E1026 Step contains invalid command. p. 367
E1035 Link Channel out of range. p. 367
E1037 Repeat Counter contains invalid channel. p. 367
E1042 Length part primary expression constant out of range. p. 367
E1043 Object code too large... p. 367
E1044 Matrix Goto out of range. p. 367
E1045 Matrix next statement out of range. p. 367
E1048 Protocol contains no message data. p. 367
E1049 Protocol contains no communication sequences. p. 367
E1050 Step contains invalid message/matrix reference p. 367
E1051 PLC xxx CPUyy does not support EM banks. p. 367
E1052 PLC xxx CPUyy supports zz EM banks. p. 367
E1053 Link Word IN1 is not defined or invalid. p. 367
E1054 Link Word OUT1 is not defined or invalid. p. 367
E1055 Link Word IN2 is not defined or invalid. p. 367
E1056 Link Word OUT2 is not defined or invalid. p. 367
E1058 Area xxx Channel yyy out of range ... p. 367
E1060 Check code LRC2 not supported on this unit. p. 367
E1061 Check code SUM1 (1byte) not supported on this unit. p. 367
E1062 Check code SUM2 (2 byte) not supported on this unit. p. 367
E1063 Header found after Terminator . p. 367
E1064 Header not at the start of the message. p. 367
E1065 Terminator not at the end of the message / before check code p. 367
W0006 Protocol will be converted. p. 367
6 NO DIAL TONE p. 374
7 BUSY p. 374
8 NO ANSWER p. 374
9 HAND SET IN USE p. 374

Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Omron. Found a mistake? Report an error.