Omron R88M-U and R88D-UT Error R.31: Deviation counter over

AC servo motor and driver · taken from the manufacturer’s manual, pages cited

Error codeR.31

The deviation counter residual pulses exceeded the level set for Cn-1E when the Servomotor did not operate even when a command pulse train was input or during high-speed rotation. The manual's first action is: “Servomotor power line or encoder line malfunction Correct the wiring.”

Model
Omron R88M-U and R88D-UT
Display shows
Deviation counter over (R.31)
Type
Error code
Source
Manual p. 139

What R.31 means

Deviation counter over p. 145

Common causes

  • Deviation counter residual pulses exceeded level set for Cn-1E. p. 145
  • Occurred when Servomotor did not operate even when command pulse train was input. p. 145
  • Occurred during high-speed rotation. p. 145
  • Occurred during long command pulse input. p. 145
  • Acceleration is too sudden. p. 145
  • Load is too large. p. 145

What to do

  1. Servomotor power line or encoder line malfunction Correct the wiring. p. 145
  2. Mechanical lock is in effect. If the Servomotor shaft is locked, unlock it. p. 145
  3. Gain adjustment is insufficient. Adjust the gain. p. 145
  4. Lengthen the acceleration time. p. 145
  5. • Lighten the load. • Select another Servomotor. p. 145

Before you service the product, read the safety instructions in the manual p. 4.

If R.31 is still not resolved

  • Consult your OMRON representative p. 4
    “Consult your OMRON representative when using the product after a long period of storage.”

This page summarises what the manufacturer’s manual says about R.31; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.