Omron R88M-U and R88D-UT Error R.10: Overcurrent

AC servo motor and driver · taken from the manufacturer’s manual, pages cited

Error codeR.10

An overcurrent was detected when power or the Servo was turned on. The manual's first action is: “Control board defective. Replace Servo Driver.”

Model
Omron R88M-U and R88D-UT
Display shows
Overcurrent (R.10)
Type
Error code
Source
Manual p. 139

What R.10 means

Overcurrent p. 145

Common causes

  • Overcurrent detected. p. 145
  • Occurred when power was turned on. p. 145
  • Occurred when Servo was turned on. p. 145
  • Servomotor power line is short-circuited or grounded. p. 145
  • There is faulty wiring at the U, V, or W phase, or the GR. p. 145
  • Servomotor coil are damaged. p. 145

What to do

  1. Control board defective. Replace Servo Driver. p. 145
  2. • Current feedback circuit error • Main circuit transistor module error Replace Servo Driver. p. 145
  3. • Correct the power line short-circuiting or grounding. • Measure the insulation resistance at the Servomotor itself. If there is short-circuiting, replace the Servomotor. p. 145
  4. Correct the wiring. p. 145
  5. Measure the winding resistance. If the coil are damaged, replace the Servomotor. p. 145

Before you service the product, read the safety instructions in the manual p. 4.

If R.10 is still not resolved

  • Consult your OMRON representative p. 4
    “Consult your OMRON representative when using the product after a long period of storage.”

This page summarises what the manufacturer’s manual says about R.10; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.