Omron R88D-WT Error ALM 4: Dynamic braking overload

AC servo driver · taken from the manufacturer’s manual, pages cited

Error codeALM 4

This code indicates dynamic braking overload, which occurs when the servo is shut down after running or when power is applied. The manual's first action is: “The energy required to stop exceeds the capacity of the dynamic braking resistor. Reduce speed. Decrease load inertia. Reduce the frequency of dynamic braking usage.”

Model
Omron R88D-WT
Display shows
Dynamic braking overload (ALM 4)
Type
Error code
Source
Manual p. 396

What ALM 4 means

Dynamic braking overload p. 396

Common causes

  • Occurs when the servo is shut down after running. p. 396
  • Occurs when power is applied. p. 396

What to do

  1. The energy required to stop exceeds the capacity of the dynamic braking resistor. Reduce speed. Decrease load inertia. Reduce the frequency of dynamic braking usage. p. 396
  2. Control panel error; replace the servo drive. p. 396

Before you service the product, read the safety instructions in the manual p. 389.

If ALM 4 is still not resolved

  • contact OMRON service or dealer p. 2
    “不注意这些事项可能导致对人体的伤害或危及财产”
  • contact OMRON service or dealer p. 389
    “相应的报警对应措施,见5-3-1用报警显示进行错误诊断”

This page summarises what the manufacturer’s manual says about ALM 4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.