Error codeALM 2

This code indicates overload, which occurs during operation or due to power supply voltage drop. The manual's first action is: “Operating above 245% of rated torque (effective torque). If the servo motor shaft is locked, repair it. If the servo motor power wiring is incorrect, rewire correctly. Reduce the load. Extend acceleration/deceleration time. Adjust gain.”

Model
Omron R88D-WT
Display shows
Overload (ALM 2)
Type
Error code
Source
Manual p. 396

What ALM 2 means

Overload p. 396

Common causes

  • Occurs during operation. p. 396
  • Power supply voltage drop. p. 396

What to do

  1. Operating above 245% of rated torque (effective torque). If the servo motor shaft is locked, repair it. If the servo motor power wiring is incorrect, rewire correctly. Reduce the load. Extend acceleration/deceleration time. Adjust gain. p. 396
  2. Check the power supply voltage and lower it to within the allowable range. p. 396

Before you service the product, read the safety instructions in the manual p. 389.

If ALM 2 is still not resolved

  • contact OMRON service or dealer p. 2
    “不注意这些事项可能导致对人体的伤害或危及财产”
  • contact OMRON service or dealer p. 389
    “相应的报警对应措施,见5-3-1用报警显示进行错误诊断”

This page summarises what the manufacturer’s manual says about ALM 2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.