This code indicates overload, which occurs during operation or due to power supply voltage drop. The manual's first action is: “Operating above 245% of rated torque (effective torque). If the servo motor shaft is locked, repair it. If the servo motor power wiring is incorrect, rewire correctly. Reduce the load. Extend acceleration/deceleration time. Adjust gain.”
- Model
- Omron R88D-WT
- Display shows
- Overload (ALM 2)
- Type
- Error code
- Source
- Manual p. 396
What ALM 2 means
Overload p. 396
Common causes
What to do
- Operating above 245% of rated torque (effective torque). If the servo motor shaft is locked, repair it. If the servo motor power wiring is incorrect, rewire correctly. Reduce the load. Extend acceleration/deceleration time. Adjust gain. p. 396
- Check the power supply voltage and lower it to within the allowable range. p. 396
Before you service the product, read the safety instructions in the manual p. 389.
If ALM 2 is still not resolved
This page summarises what the manufacturer’s manual says about ALM 2; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.