The command warning means the command was not executed due to not being ready, a servo lock attempt while the main circuit is open, or parameter reading/writing while communicating with WMON. The manual's first action is: “If this warning occurs under any of the above conditions, stop the operation that caused the warning, then retry.”
- Model
- Omron R88D-WT
- Display shows
- Command warning (A.95)
- Type
- Warning code
- Source
- Manual p. 437
What A.95 means
Command warning p. 437
Common causes
- Not ready to execute the command received via MECHATROLINK-II communication, so the command was not executed. p. 437
- Attempted to execute a servo lock while the servo drive's main circuit is open. p. 437
- Reading or writing main controller (including supporting software) or servo drive parameters while communicating with WMON. p. 437
- The same node number was set twice. p. 437
What to do
- If this warning occurs under any of the above conditions, stop the operation that caused the warning, then retry. p. 437
Before you service the product, read the safety instructions in the manual p. 389.
If A.95 is still not resolved
This page summarises what the manufacturer’s manual says about A.95; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.