Omron R88D-WT Error A.E6: Communication error

AC servo driver · taken from the manufacturer’s manual, pages cited

Error codeA.E6

This code indicates a communication error, which occurs when there are two consecutive MECHATROLINK-II communication errors. The manual's first action is: “• Check that the communication cable (cable and connectors) is making proper contact. • The encoder may be affected by noise. Implement noise-reduction measures, such as isolating the encoder wiring from the main-circuit power lines.”

Model
Omron R88D-WT
Display shows
Communication error (A.E6)
Type
Error code
Source
Manual p. 436

What A.E6 means

Communication error p. 436

Common causes

  • Two consecutive MECHATROLINK-II communication errors. p. 436

What to do

  1. • Check that the communication cable (cable and connectors) is making proper contact. • The encoder may be affected by noise. Implement noise-reduction measures, such as isolating the encoder wiring from the main-circuit power lines. p. 436

Before you service the product, read the safety instructions in the manual p. 389.

If A.E6 is still not resolved

  • contact OMRON service or dealer p. 2
    “不注意这些事项可能导致对人体的伤害或危及财产”
  • contact OMRON service or dealer p. 389
    “相应的报警对应措施,见5-3-1用报警显示进行错误诊断”

This page summarises what the manufacturer’s manual says about A.E6; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.