Omron OMNUC W Series Error A.83: battery error

Omron OMNUC W Series AC Servomotors Servo Drivers · taken from the manufacturer’s manual, pages cited

Alarm codeA.83

The manual lists this code without a description. The manual's first action is: “Replace the absolute encoder backup battery if it has been used for at least five years, or if an A.83 (battery error) alarm occurs.”

Model
Omron OMNUC W Series
Display shows
battery error (A.83)
Type
Alarm code
Source
Manual p. 379

What A.83 means

battery error p. 379

What to do

  1. Replace the absolute encoder backup battery if it has been used for at least five years, or if an A.83 (battery error) alarm occurs. p. 379

Before you service the product, read the safety instructions in the manual p. 6.

If A.83 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Omron service.

This page summarises what the manufacturer’s manual says about A.83; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Omron. Found a mistake? Report an error.