OPE |
Abnormal parameter setting when configuring MEMOBUS communication parameters | MEMOBUS通信参数设定时,参数设定异常 |
p. 127 |
OP1 |
Abnormal setting value for multifunction input selection (parameters n030–n056) | 多功能输入选择的设定值异常 (参数n030~056) |
p. 127 |
OP2 |
Conflicting magnitude relationships in V/f parameter settings (parameters n011, p13, p14, p16) | V/f参数设定的大小关系有矛盾。(参数n011p13p14p16) |
p. 127 |
OP3 |
The set value for motor rated voltage exceeds 130% of the inverter’s rated voltage (parameter n036) | 电机额定电压高的设定值超过变频器额定的130%。(参数n036) |
p. 127 |
OP4 |
Upper and lower limits of frequency command are reversed (parameters n033, n034) | 频率指令上限和下限大小相反 (参数n033,034) |
p. 127 |
OP5 |
Conflicting magnitude relationships among jump frequency parameters 1, 2, and 3 (parameters n033, n034, n035) | 跳频参数1,2,3的大小关系有矛盾 (参数n033,034,035) |
p. 127 |
OP9 |
Incorrect negative frequency setting (parameter n080) | 负数频率设定不正确 (参数n080) |
p. 127 |
BB |
Inverter output is cut off after external base plate lock (note: operation restarts after external basic delay is released) | 外部基板锁定后,变频器输出切断 (注: 外部基本延时解除后运行重新开始) |
p. 127 |
ER |
When forward and reverse commands are simultaneously applied / the forward and reverse command terminals of the control circuit are both set to “ON”, the inverter stops according to the stop method setting (parameter n005) | 正转/反转指令同时投入/控制回路端子的正转指令和反转指令同时为“用”时,按停止方法选择的设定(参数n005)变频器停止 |
p. 127 |
FAN |
Cooling fan abnormal / fan jammed | 冷却风扇异常/冷却风扇被卡住了 |
p. 127 |
CE |
MEMOBUS communication error / communication data not received properly | MEMOBUS通信异常/通信数据不能正常受信 |
p. 127 |
EF |
When forward and reverse commands are simultaneously applied / forward and reverse command terminals of the control circuit are both “ON” for more than 500 ms, the inverter stops according to the stop method setting (parameter n005) | 正转/反转指令同时投入/控制回路端子的正转指令和反转指令同时为“用”、500ms以上“用”时,按停止方法选择的设定(参数n005)变频器停止 |
p. 128 |
FAN1 |
Cooling fan abnormal / fan jammed | 冷却风扇异常/冷却风扇被卡住了 |
p. 128 |
OC |
Overcurrent | 过电流 |
p. 130 |
OL |
Protection action | 保护动作 |
p. 130 |
UV1 |
Main circuit low voltage | 主回路低电压 |
p. 130 |
Uu2 |
After power is cut and re‑applied, if the abnormality persists, replace the inverter. Check for loose screws | 一旦切断电源后,再投入。异常继续发生时,更换变频器。螺丝是否松动 |
p. 131 |
OH |
OH (cooling heat‑sink overtemperature) | OH (冷却散热过热) |
p. 131 |
OL1 |
OL1 (motor overload) | OL1(电机过载) |
p. 131 |
OL2 |
OL2 (inverter overload) | OL2(变频器过载) |
p. 131 |
OL3 |
OL3 (over‑torque detection) | OL3(过转矩检测) |
p. 131 |
EF3 |
External abnormal command received from control circuit terminal S3 | 从控制回路端子 S3 来的外部异常指令 |
p. 132 |
EF4 |
External abnormal command received from control circuit terminal S4 | 从控制回路端子 S4 来的外部异常指令 |
p. 132 |
EF5 |
External abnormal command received from control circuit terminal S5 | 从控制回路端子 S5 来的外部异常指令 |
p. 132 |
EF6 |
External abnormal command received from control circuit terminal S6 | 从控制回路端子 S6 来的外部异常指令 |
p. 132 |
EF7 |
External abnormal command received from control circuit terminal S7 | 从控制回路端子 S7 来的外部异常指令 |
p. 132 |
CPP.00 |
Communication with the operator cannot be established even after 5 seconds of power-on | 电源投入 5 秒后,也无法建立与操作器的通信 |
p. 132 |
CPP.01 |
Transmission error occurs more than 5 seconds after communication with the operator begins | 与操作器的传输开始后,5秒以上传送异常发生 |
p. 132 |